TY - JOUR
T1 - Time to Refocus Assessment of Vision in Older Adults? Contrast Sensitivity but Not Visual Acuity Is Associated with Gait in Older Adults
AU - Duggan, Eoin
AU - Donoghue, Orna
AU - Kenny, Rose Anne
AU - Cronin, Hilary
AU - Loughman, James
AU - Finucane, Ciarán
N1 - Publisher Copyright:
© The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: [email protected].
PY - 2017/11/9
Y1 - 2017/11/9
N2 - Background The relationship between measures of visual function and gait related risk factors for falls is unclear. In this study, we examine the relationship between visual function (visual acuity [VA] and contrast sensitivity [CS] at multiple spatial frequencies) and quantitative spatiotemporal gait, using a large, nationally representative sample of community dwelling older adults. Methods Participants aged 50 and over were recruited as part of The Irish Longitudinal Study on Ageing (TILDA). VA was measured with the LogMAR chart according to the Early Treatment of Diabetic Retinopathy Study protocol. CS was measured at five spatial frequencies ranging 1.5 to 18 cycles per degree (cpd) using the Functional Acuity Contrast Test. Gait speed, cadence, and stride length were measured using the GAITRite system. Multivariate analysis examined associations between gait and visual performance parameters adjusting for socioeconomic, physical, cognitive, and mental health covariates. Results Data from 4,678 participants were analyzed (age 61.7 ± 8.3 years, 54.1% woman). Poorer CS at 1.5 cpd and 3.0 cpd (low spatial frequency) was independently associated with decreased stride length (CS at 1.5 cpd: β =.031; p =.001 and CS at 3.0 cpd: β =.020; p =.001) but not cadence or gait speed. There was no evidence of an association between VA and any of the gait variables considered (p >.05). Conclusion Reduced CS, at low spatial frequencies, is independently associated with shorter stride length, while VA is not associated with any gait measures. This evidence suggests that it may be necessary to consider refocus of the assessment of vision to include the most appropriate measures.
AB - Background The relationship between measures of visual function and gait related risk factors for falls is unclear. In this study, we examine the relationship between visual function (visual acuity [VA] and contrast sensitivity [CS] at multiple spatial frequencies) and quantitative spatiotemporal gait, using a large, nationally representative sample of community dwelling older adults. Methods Participants aged 50 and over were recruited as part of The Irish Longitudinal Study on Ageing (TILDA). VA was measured with the LogMAR chart according to the Early Treatment of Diabetic Retinopathy Study protocol. CS was measured at five spatial frequencies ranging 1.5 to 18 cycles per degree (cpd) using the Functional Acuity Contrast Test. Gait speed, cadence, and stride length were measured using the GAITRite system. Multivariate analysis examined associations between gait and visual performance parameters adjusting for socioeconomic, physical, cognitive, and mental health covariates. Results Data from 4,678 participants were analyzed (age 61.7 ± 8.3 years, 54.1% woman). Poorer CS at 1.5 cpd and 3.0 cpd (low spatial frequency) was independently associated with decreased stride length (CS at 1.5 cpd: β =.031; p =.001 and CS at 3.0 cpd: β =.020; p =.001) but not cadence or gait speed. There was no evidence of an association between VA and any of the gait variables considered (p >.05). Conclusion Reduced CS, at low spatial frequencies, is independently associated with shorter stride length, while VA is not associated with any gait measures. This evidence suggests that it may be necessary to consider refocus of the assessment of vision to include the most appropriate measures.
KW - Contrast sensitivity
KW - Falls
KW - Visual acuity
UR - http://www.scopus.com/inward/record.url?scp=85038129962&partnerID=8YFLogxK
U2 - 10.1093/gerona/glx021
DO - 10.1093/gerona/glx021
M3 - Article
C2 - 28329377
AN - SCOPUS:85038129962
SN - 1079-5006
VL - 72
SP - 1663
EP - 1668
JO - Journals of Gerontology - Series A Biological Sciences and Medical Sciences
JF - Journals of Gerontology - Series A Biological Sciences and Medical Sciences
IS - 12
ER -