TY - JOUR
T1 - Development and validation of a rapid method for the determination and confirmation of 10 nitroimidazoles in animal plasma using liquid chromatography tandem mass spectrometry
AU - Cronly, Mark
AU - Behan, Patrice
AU - Foley, Barry
AU - Malone, Edward
AU - Regan, Liam
PY - 2009/5/15
Y1 - 2009/5/15
N2 - A rapid LC-MS/MS method has been developed and validated for the simultaneous identification, confirmation and quantitation of 10 nitroimidazoles in plasma. The method validated in accordance with Commission Decision (CD) 2002/657/EC is capable of analysing for metronidazole (MNZ), dimetridazole (DMZ), ronidazole (RNZ), ipronidazole (IPZ) and their hydroxy metabolites MNZ-OH, HMMNI (hydroxymethyl, methyl nitroimidazole), IPZ-OH. The method is also capable of analysing carnidazole (CRZ), ornidazole (ORZ) and ternidazole (TRZ) which are rarely analysed by modern methods. MNZ, DMZ and RNZ have a recommended level (RL) of 3 ng mL-1 which this method is easily able to detect for all the nitroimidazole compounds. Plasma samples are extracted with acetonitrile, and NaCl is added to help remove matrix contaminants. The acetonitrile extract undergoes a liquid-liquid wash step with hexane; it is then evaporated and reconstituted in mobile phase. The reconstituted samples are analysed by liquid chromatography tandem mass spectrometry (LC-MS/MS). The decision limits (CCα) range from 0.5 to 1.6 ng mL-1 and the detection capabilities (CCβ), range from 0.8 to 2.6 ng mL-1. The results of the inter-assay study, which was performed by fortifying bovine plasma samples (n = 18) on three separate days, show the accuracy calculated for the various analytes range between 101% and 108%. The precision of the method, expressed as CV% values for the inter-assay variation of each analyte at the three levels of fortification (3, 4.5 and 6.0 ng mL-1), ranged between 4.9% and 15.2%. A day 4 analysis was carried out to examine species variances in animals such as avian, ovine, porcine and equine.
AB - A rapid LC-MS/MS method has been developed and validated for the simultaneous identification, confirmation and quantitation of 10 nitroimidazoles in plasma. The method validated in accordance with Commission Decision (CD) 2002/657/EC is capable of analysing for metronidazole (MNZ), dimetridazole (DMZ), ronidazole (RNZ), ipronidazole (IPZ) and their hydroxy metabolites MNZ-OH, HMMNI (hydroxymethyl, methyl nitroimidazole), IPZ-OH. The method is also capable of analysing carnidazole (CRZ), ornidazole (ORZ) and ternidazole (TRZ) which are rarely analysed by modern methods. MNZ, DMZ and RNZ have a recommended level (RL) of 3 ng mL-1 which this method is easily able to detect for all the nitroimidazole compounds. Plasma samples are extracted with acetonitrile, and NaCl is added to help remove matrix contaminants. The acetonitrile extract undergoes a liquid-liquid wash step with hexane; it is then evaporated and reconstituted in mobile phase. The reconstituted samples are analysed by liquid chromatography tandem mass spectrometry (LC-MS/MS). The decision limits (CCα) range from 0.5 to 1.6 ng mL-1 and the detection capabilities (CCβ), range from 0.8 to 2.6 ng mL-1. The results of the inter-assay study, which was performed by fortifying bovine plasma samples (n = 18) on three separate days, show the accuracy calculated for the various analytes range between 101% and 108%. The precision of the method, expressed as CV% values for the inter-assay variation of each analyte at the three levels of fortification (3, 4.5 and 6.0 ng mL-1), ranged between 4.9% and 15.2%. A day 4 analysis was carried out to examine species variances in animals such as avian, ovine, porcine and equine.
KW - Liquid chromatography tandem mass spectrometry
KW - Method validation
KW - Nitroimidazoles
KW - Plasma
UR - http://www.scopus.com/inward/record.url?scp=65349168316&partnerID=8YFLogxK
U2 - 10.1016/j.jchromb.2009.03.030
DO - 10.1016/j.jchromb.2009.03.030
M3 - Article
C2 - 19345159
AN - SCOPUS:65349168316
SN - 1570-0232
VL - 877
SP - 1494
EP - 1500
JO - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
JF - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
IS - 14-15
ER -