TY - JOUR
T1 - Comparison of cycloplegia at 20- and 30-minutes following proxymetacaine and cyclopentolate instillation in white 12-13-year-olds
AU - Doyle, Megan
AU - O’ Dwyer, Veronica
AU - Harrington, Síofra
N1 - Publisher Copyright:
© 2023 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group.
PY - 2023
Y1 - 2023
N2 - Clinical Relevance: Reducing the time between drop instillation and refraction reduces the time paediatric patients and young adults spend in practice, facilitating more eye examinations daily. Background: The current procedure for paediatric cycloplegic refraction is to wait for at least 30-minutes post-instillation of a cycloplegic before measuring spherical equivalent refraction. This study compared cycloplegia at 20- and 30-minutes following 0.5% proxymetacaine and 1.0% cyclopentolate in 12-13-year-olds. Methods: Participants were 99 white 12-13-year-olds. One drop of proxymetacaine hydrochloride (Minims, 0.5% w/v, Bausch & Lomb, UK) followed by one drop of cyclopentolate hydrochloride (Minims, 1.0% w/v, Bausch & Lomb, UK) was instilled into both eyes. Spherical equivalent refraction was measured by autorefraction (Dong Yang Rekto ORK-11 Auto Ref-Keratometer) at 20- and 30-minutes post-instillation. Data were analysed through paired t-testing, correlations, and linear regression analysis. Results: There was no significant difference in level of cycloplegia achieved at 20- (Mean spherical equivalent refraction (standard deviation) 0.438 (1.404) D) and 30-minutes (0.487 (1.420) D) post-eyedrop instillation (t (98) = 1.667, p = 0.099). The mean spherical equivalent refraction difference between time points was small (0.049 (0.294) D, 95% confidence interval =-0.108 ̶ 0.009D). Agreement indices: Accuracy = 0.999, Precision = 0.973, Concordance = 0.972. Spherical equivalent refraction at 20- and 30-minutes differed by ≤0.50D in 92% of eyes, and by <1.00D in 95%. Conclusions: There was no clinically significant difference in spherical equivalent refraction or level of cycloplegia at 20- and 30-minutes post-eyedrop instillation. The latent time between drop instillation and measurement of refractive error may be reduced to 20 minutes in White 12-13-year-olds and young adults. Further studies must determine if these results persist in younger children and non-White populations.
AB - Clinical Relevance: Reducing the time between drop instillation and refraction reduces the time paediatric patients and young adults spend in practice, facilitating more eye examinations daily. Background: The current procedure for paediatric cycloplegic refraction is to wait for at least 30-minutes post-instillation of a cycloplegic before measuring spherical equivalent refraction. This study compared cycloplegia at 20- and 30-minutes following 0.5% proxymetacaine and 1.0% cyclopentolate in 12-13-year-olds. Methods: Participants were 99 white 12-13-year-olds. One drop of proxymetacaine hydrochloride (Minims, 0.5% w/v, Bausch & Lomb, UK) followed by one drop of cyclopentolate hydrochloride (Minims, 1.0% w/v, Bausch & Lomb, UK) was instilled into both eyes. Spherical equivalent refraction was measured by autorefraction (Dong Yang Rekto ORK-11 Auto Ref-Keratometer) at 20- and 30-minutes post-instillation. Data were analysed through paired t-testing, correlations, and linear regression analysis. Results: There was no significant difference in level of cycloplegia achieved at 20- (Mean spherical equivalent refraction (standard deviation) 0.438 (1.404) D) and 30-minutes (0.487 (1.420) D) post-eyedrop instillation (t (98) = 1.667, p = 0.099). The mean spherical equivalent refraction difference between time points was small (0.049 (0.294) D, 95% confidence interval =-0.108 ̶ 0.009D). Agreement indices: Accuracy = 0.999, Precision = 0.973, Concordance = 0.972. Spherical equivalent refraction at 20- and 30-minutes differed by ≤0.50D in 92% of eyes, and by <1.00D in 95%. Conclusions: There was no clinically significant difference in spherical equivalent refraction or level of cycloplegia at 20- and 30-minutes post-eyedrop instillation. The latent time between drop instillation and measurement of refractive error may be reduced to 20 minutes in White 12-13-year-olds and young adults. Further studies must determine if these results persist in younger children and non-White populations.
KW - Cyclopentolate
KW - cycloplegia
KW - proparacaine
KW - proxymetacaine
KW - refractive errors
UR - http://www.scopus.com/inward/record.url?scp=85147686636&partnerID=8YFLogxK
U2 - 10.1080/08164622.2023.2166398
DO - 10.1080/08164622.2023.2166398
M3 - Article
C2 - 36750050
AN - SCOPUS:85147686636
SN - 0816-4622
VL - 106
SP - 890
EP - 895
JO - Clinical and Experimental Optometry
JF - Clinical and Experimental Optometry
IS - 8
ER -