TY - GEN
T1 - Assessment of the effects of increasing levels of physiological realism in the computational fluid dynamics analyses of implanted coronary stents
AU - Murphy, J.
AU - Boyle, F.
PY - 2008
Y1 - 2008
N2 - Coronary stent implantation can improve blood flow in an artery that has been narrowed by the build up of arterial plaque. However, the implantation of the stent will change the geometry of the vessel wall. The haemodynamic effects of the stents presence and alteration of the vessel wall are unclear. The redistribution of flow induced vessel wall shear stress (WSS) and wall shear stress gradient (WSSG) may directly contribute to restenosis (re-blockage). Computational fluid dynamics (CFD) is used extensively to identify these parameters in stented vessels. However, simplifications to the model of the stented artery are common. In this paper, computational domains of stented arteries with increasing levels of physiological realism are created. CFD is used to predict the WSS and WSSG for each set of computational domains. Finally, the results show that certain simplifications are not valid for CFD analyses of implanted coronary stents.
AB - Coronary stent implantation can improve blood flow in an artery that has been narrowed by the build up of arterial plaque. However, the implantation of the stent will change the geometry of the vessel wall. The haemodynamic effects of the stents presence and alteration of the vessel wall are unclear. The redistribution of flow induced vessel wall shear stress (WSS) and wall shear stress gradient (WSSG) may directly contribute to restenosis (re-blockage). Computational fluid dynamics (CFD) is used extensively to identify these parameters in stented vessels. However, simplifications to the model of the stented artery are common. In this paper, computational domains of stented arteries with increasing levels of physiological realism are created. CFD is used to predict the WSS and WSSG for each set of computational domains. Finally, the results show that certain simplifications are not valid for CFD analyses of implanted coronary stents.
UR - http://www.scopus.com/inward/record.url?scp=61849099326&partnerID=8YFLogxK
U2 - 10.1109/iembs.2008.4650559
DO - 10.1109/iembs.2008.4650559
M3 - Conference contribution
C2 - 19164062
AN - SCOPUS:61849099326
SN - 9781424418152
T3 - Proceedings of the 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'08 - "Personalized Healthcare through Technology"
SP - 5906
EP - 5909
BT - Proceedings of the 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'08
PB - IEEE Computer Society
T2 - 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'08
Y2 - 20 August 2008 through 25 August 2008
ER -