A Numerical Acoustic Fluid-structure Simulation of Therapeutic Ultrasound Angioplasty

Graham Gavin, Finbar Dolan, M.S J Hashmi, Garrett McGuinness

Research output: Contribution to conferencePaperpeer-review

Abstract

INTRODUCTION Therapeutic ultrasound angioplasty is the delivery of high amplitude ultrasonic displacements to the distal-tip of small diameter wire waveguides with the goal of disrupting atherosclerotic plaques. This is a minimally invasive procedure that may have potential' in the treatment of complicated chronic total occlusions. The disruption of plaque is due to direct contact ablation and also cavitation, pressure waves and acoustic streaming in the fluid surrounding the vibrating waveguide distal-tip [1]. Cavitation appears to play a major role and some authors have suggested that plaque ablation is only evident above the cavitation threshold [2]. Makin and Everbach [3] performed experimental measurements of the acoustic pressures in the field surrounding a vibrating wire waveguide distal-tip (frequency = 22.5 kHz, displacement amplitude = 651lm, tip diameter = 2.46mm). The measured acoustic pressures in the region ahead of the distal-tip are shown in Figure I. No measurements could be made in the region close to the tip but the authors concluded that these pressures would be sufficient to cause the cavitation that was observed, based on the trend in Figure I. This work describes a numerical acoustic fluidstructure model of the wire waveguide and fluid surrounding the distal-tip. The model will predict wire waveguide behaviour to a prescribed ultrasonic input displacement and will predict pressures developed around the distal-tip. METHODS An axisymmetric numerical model of the wire waveguide and fluid surrounding the distal-tip based on the device description by Makin and Everbach [3] was developed in ANSYS©. The model consisted of both structural elements (Plane42) for the waveguide and acoustic elements (Fluid29) for the fluid. A tluidstructure interface was placed at element couplings and infinite acoustic boundary elements (Fluid 129) defined the extremities of the model preventing acoustic reflection RESULTS A comparison of the experimental [3] and the numerical results are shown in Figure l. A close comparison is achieved and, in addition, the numerical model can predict pressures at the fluid-structure interface. With the inclusion of a cavitation threshold (CT), displacements and frequencies required to cause cavitation can be predicted. CONCLUSION The validated model can be used to investigate the effects of changing device parameters such as frequency of operation, displacement amplitudes and geometry, on both waveguide structural response (displacements and stresses) and pressures developed in the surrounding fluid.
Original languageEnglish
DOIs
Publication statusPublished - 2006
EventBioengineering In Ireland Conference - Galway, Ireland
Duration: 27 Jan 200628 Jan 2006

Conference

ConferenceBioengineering In Ireland Conference
Country/TerritoryIreland
CityGalway
Period27/01/0628/01/06

Keywords

  • therapeutic ultrasound angioplasty
  • ultrasonic displacements
  • atherosclerotic plaques
  • minimally invasive procedure
  • chronic total occlusions
  • cavitation
  • pressure waves
  • acoustic streaming
  • numerical model
  • fluid-structure interface
  • cavitation threshold